Corexit 9527   6-14-92 version only mentions 2-butoxyethanol as an ingredient, Look closer and you see it has 38% 2-butoxyethanol  *

Copy mailed by company 1-3-03... is this same msds  *

not ethylene oxide as in the 8-1-89 version  

(may still be an ingredient?)

EXXON CHEMICAL AMERICAS DIV EX -- COREXIT 9527                                 
=======================================================
MSDS Safety Information 
=======================================================
FSC: 6850
MSDS Date: 06/14/1992
MSDS Num: BRYBG
LIIN: 00F030320
Product ID: COREXIT 9527
MFN: 01
Responsible Party
Cage: 72190
Name: EXXON CHEMICAL AMERICAS DIV EXXON CORP
Box: 3272
City: HOUSTON TX 77001
Info Phone Number: 713-870-6000
Emergency Phone Number: 713-870-6000
Review Ind: Y
Published: Y
=======================================================
Preparer Co. when other than Responsible Party Co. 
=======================================================
Cage: 72190
Name: EXXONMOBIL CHEMICAL CO, DIV OF EXXON MOBILCORP.
Address: 13501 KATY FWY
Box: 3272
City: HOUSTON TX 77253-3272
=======================================================
Contractor Summary 
=======================================================
Cage: 72190
Name: EXXONMOBIL CHEMICAL CO, DIV OF EXXON MOBILCORP.
Address: 13501 KATY FWY
Box: 3272
City: HOUSTON TX 77253-3272
Phone: 281-870-6000 / 800-726-2015
=======================================================
Ingredients 
=======================================================
Cas: 111-76-2
RTECS #: KJ8575000
Name: 2-BUTOXYETHANOL (ETHYLENEGLYCOL MONOBUTYL ETHER), BUTYL CELLOSOLVE, BUTYL
  GLYCOL, GLYCOL ETHER EB
% Wt: 38
Other REC Limits: 25 PPM (SKIN)
OSHA PEL: S, 50 PPM
ACGIH TLV: S, 25 PPM; 9293
=======================================================
Health Hazards Data 
=======================================================
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: EYES: IRRITATING, MAY INJURE TISSUE IF NOT REMOVED
  PROMPTLY. SKIN: IRRITATING. ABSORPTION MAY CAUSE HEMOLYTIC ANEMIA &
  KIDNEY DAMAGE EVIDENCED BY PALENESS & RED COLORATION OF URINE.
  INHALATION: RESPIR ATORY TRACT IRRITATION. SYSTEMIC EFFECTS. INGESTION: LOW
  TOXICITY. INHALATION/SKIN OVEREXPOSURE: BLOOD/KIDNEY DAMAGE.
Explanation Of Carcinogenicity: NONE
First Aid: EYES: FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINS. SKIN: FLUSH
  W/PLENTY OF WATER. USE SOAP IF AVAILABLE. REMOVE CONTAMINATED CLOTHING,
  INCLUDING SHOES, AFTER FLUSHING HAS BEGUN. INHALATION: REMOVE TO  FRESH AIR.
  ADMINISTER ARTIFICIAL RESPIRATION IF BREATHING IS STOPPED. KEEP AT REST.
  INGESTION: INDUCE VOMITING. DON'T ATTEMPT TO GIVE ANYTHING BY MOUTH TO AN
  UNCONSCIOUS PERSON. OBTAIN MED ATTN.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: ELIMINATE IGNITION SOURCES. SMALL/LARGE SPILL:
  IMPLEMENT CLEANUP PROCECURES. FOR LARGE IF IN PUBLIC AREA, EVACUATE AREA.
  CONTAIN LIQUID W/SAND/EARTH. DON'T USE COMBUSTIBLES. RECOVER BY PUMPING
  (EXPLOS ION PROOF/HAND PUMP) OR W/A SUITABLE ABSORBENT.
Waste Disposal Methods: DISPOSE OF IN ACCORDANCE W/LOCAL, STATE, & FEDERAL
  REGULATIONS. PREVENT LIQUID FROM ENTERING SEWERS, WATERCOURSES OR LOW AREAS.
  COMPLETELY DRAIN, PROPERLY BUNG & PROMPTLY RETURN EMPTY DRUMS TO A DRUM 
  RECONDITIONER OR PROPERLY DISPOSED OF. NA 1993
Other Precautions: EMPTY CONTAINERS RETAIN RESIDUE & CAN BE DANGEROUS.
  DON'T PRESSURIZE/CUT/WELD/BRAZE/SOLDER/DRILL/GRIND/EXPOSE SUCH CONTAINERS TO
  HEAT/FLAME/SPARKS/ELECRICITY/OTHER IGNITION SOURCES; THEY MAY EXPLODE & 
  CAUSE INJURY OR DEATH.
=======================================================
Fire and Explosion Hazard Information 
=======================================================
Flash Point Method: TCC
Flash Point Text: 163F
Lower Limits: 1.1%
Upper Limits: 10.6%
Extinguishing Media: ALCOHOL TYPE FOAM, DRY CHEMICAL OR WATER SPRAY
Fire Fighting Procedures: USE WATER SPRAY TO COOL FIRE EXPOSED SURFACES &
  TO PROTECT PERSONNEL. ISOLATE FUEL SUPPLY FROM FIRE. AVOID SPRAYING WATER
  DIRECTLY INTO STORAGE CONTAINERS.
Unusual Fire/Explosion Hazard: COMBUSTIBLE LIQUID, CAN FORM COMBUSTIBLE
  MIXTURES AT TEMPS AT OR ABOVE THE FLASHPOINT.
=======================================================
Control Measures 
=======================================================
Respiratory Protection: IF THE TLV HAS BEEN EXCEEDED, USE A NIOSH/MSHA APPROVED
  RESPIRATOR.
Ventilation: LOCAL EXHAUST. STORE & HANDLE LABORATORY SAMPLES IN A LAB
  HOOD. PROVIDE MECHANICAL VENTILATION IN CONFINED AREAS.
Protective Gloves: CHEMICAL RESISTANT
Eye Protection: CHEMICAL SAFETY GOGGLES W/FACE SHIELD
Other Protective Equipment: CHEMICAL SUIT, RUBBER BOOTS, LONG SLEEVE CLOTHING.
=======================================================
Physical/Chemical Properties 
=======================================================
B.P. Text: 340F
M.P/F.P Text: -45F
Vapor Pres: 5
Spec Gravity: 1
Evaporation Rate & Reference: (N-BU AC = 1): 0.1
Solubility in Water: COMPLETE
Appearance and Odor: AMBER LIQUID W/GLYCOL ETHER ODOR.
=======================================================
Reactivity Data 
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: HEAT, FLAME, SPARKS, STATIC ELECTRICITY OR OTHER
  SOURCES OF IGNITION.
Materials To Avoid: STRONG OXIDIZING AGENTS
Hazardous Decomposition Products: SMOKE FUMES, CO, CO2
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information 
=======================================================
=======================================================
Ecological Information 
=======================================================
=======================================================
MSDS Transport Information 
=======================================================
=======================================================
Regulatory Information 
=======================================================
=======================================================
Other Information 
=======================================================
=======================================================
HAZCOM Label 
=======================================================
Product ID: COREXIT 9527
Cage: 72190
Company Name: EXXONMOBIL CHEMICAL CO, DIV OF EXXON MOBILCORP.
Street: 13501 KATY FWY
PO Box: 3272
City: HOUSTON TX
Zipcode: 77253-3272
Health Emergency Phone: 713-870-6000
Label Required IND: Y
Date Of Label Review: 09/30/1993
Status Code: C
Label Date: 09/30/1993
Origination Code: F
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Severe
Contact Hazard: Severe
Fire Hazard: Moderate
Reactivity Hazard: Slight
Hazard And Precautions: EYES: IRRITATING, MAY INJURE TISSUE IF NOT REMOVED
  PROMPTLY. SKIN: IRRITATING. ABSORPTION MAY CAUSE HEMOLYTIC ANEMIA &
  KIDNEY DAMAGE EVIDENCED BY PALENESS & RED COLORATION OF URINE.
  INHALATION: RESPIR ATORY TRACT IRRITATION. SYSTEMIC EFFECTS. INGESTION: LOW
  TOXICITY. INHALATION/SKIN OVEREXPOSURE: BLOOD/KIDNEY DAMAGE. TARGET ORGANS:
  EYES, SKIN, KIDNEYS, RESPIRATORY TRACT, BLOOD.		    T ARGET
  ORGANS: EYES, SKIN, LIVER, KIDNEYS, RESPIRATORY & DIGESTIVE TRACTS,
  HEART.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
  information is formulated for use by elements of the Department of Defense.
  The United States of America in no manner whatsoever expressly or implied
  warrants, states, or intends said information to have any application, use or
  viability by or to any person or persons outside the Department of Defense
  nor any person or persons contracting with any instrumentality of the United
  States of America and disclaims all liability for such use. Any person
  utilizing this instruction who is not a military or civilian employee of the
  United States of America should seek competent professional advice to verify
  and assume responsibility for the suitability of this information to their
  particular situation regardless of similarity to a corresponding Department
  of Defense or other government situation.

http://hazard.com/msds/f/bry/brybg.html

Do you really think they will properly suit up the workers and all those who transport this in "moon-suit' attire?

More info